Operating instructions
Instructions for use
- It is recommended to check that the gloves are suitable for the intended use, because the conditions of use at workplace may differ from the "CE"-type tests.
- It is not recommended for persons sensitized to dithiocarbamates to use these gloves.
- Put the gloves on dry, clean hands.
- Do not use the gloves in contact with a chemical for a duration in excess of the measured breakthrough time. Refer to the website www.mapa-pro.com or contact the Technical Customer Service - MAPA PROFESSIONNEL (stc.mapaspontex@mapaspontex.fr) in order to know this breakthrough time. Use 2 pairs alternatively when in long duration contact with a solvent.
- Turn the cuff end down in order to prevent a hazardous chemical from dripping onto the arm.
Storage conditions
Store the gloves in their original packaging at a temperature not below 5°C.
Laundering conditions
Before taking off the gloves, clean them as appropriate :
- in use with paints, pigments and inks : wipe with a clean cloth dampened with a suitable solvent, and rub over with a dry cloth
- in use with a solvent (diluents, etc...) : rub over with a dry cloth
- in use with acids or alkalies : thoroughly rinse the gloves under running water, and rub over with a dry cloth
Caution : using the gloves or submitting them to cleaning or laundering process which are not specifically recommended can alter their performance levels.
Drying conditions
Ensure the inside of the gloves is dry before putting them on again.
Legislation
This product is not classified as hazardous according to the directive 1999/45/EC of the European Parliament and of the Council.
This product does not contain any substances of very high concern according to the regulation n° 1907/2006 of the European Parliament and of the Council (REACH).
Chemical chart
Chemical Product |
CAS # |
BTT (minutes) |
Permeation level |
Standard |
Degradation level |
Rating |
2-Butoxyethanol (Butyl Cellusolve) 99% |
111-76-2 |
480 |
6 |
EN 374-3:2003 |
3 |
++
|
Butyl Acetate 99% |
123-86-4 |
88 |
3 |
ASTM F739 |
NT |
NA
|
Dichloromethane (Methylene Chloride) 99% |
75-09-2 |
16 |
1 |
ASTM F739 |
1 |
-
|
Diethylamine 98% |
109-89-7 |
38 |
2 |
EN 374-3:2003 |
1 |
-
|
Methanol 85% |
67-56-1 |
480 |
6 |
EN 374-3:2003 |
4 |
++
|
Methanol 99% |
67-56-1 |
480 |
6 |
EN 374-3:2003 |
4 |
++
|
Methyl Ethyl Ketone (2-Butanone) 99% |
78-93-3 |
43 |
2 |
EN 374-3:2003 |
1 |
-
|
Naphtha, Hydrodesulphurized Heavy mixture |
64742-82-1 |
359 |
5 |
EN 374-3:2003 |
3 |
++
|
Nitric acid 10% |
7697-37-2 |
480 |
6 |
EN 374-3:2003 |
NT |
NA
|
Nitric acid 20% |
7697-37-2 |
480 |
6 |
EN 374-3:2003 |
NT |
NA
|
Nitric acid 40% |
7697-37-2 |
480 |
6 |
EN 374-3:2003 |
NT |
NA
|
Nitric acid 50% |
7697-37-2 |
480 |
6 |
EN 374-3:2003 |
NT |
NA
|
Nitric acid 68% |
7697-37-2 |
480 |
6 |
EN 374-3:2003 |
3 |
++
|
Styrene 99% |
100-42-5 |
35 |
2 |
EN 374-3:2003 |
1 |
-
|
Sulfuric acid 10% |
7664-93-9 |
480 |
6 |
ASTM F739 |
4 |
++
|
Sulfuric acid 40% |
7664-93-9 |
480 |
6 |
ASTM F739 |
4 |
++
|
Sulfuric acid 50% |
7664-93-9 |
480 |
6 |
ASTM F739 |
4 |
++
|
Sulfuric acid 96% |
7664-93-9 |
480 |
6 |
ASTM F739 |
4 |
++
|
Toluene 99% |
108-88-3 |
26 |
1 |
ASTM F739 |
NT |
NA
|
Trichloroethylene 99% |
79-01-6 |
21 |
1 |
EN 374-3:2003 |
1 |
-
|
Xylene 99% |
1330-20-7 |
50 |
2 |
EN 374-3:2003 |
1 |
-
|
*not normalized result
Overall Chemical Protection Rating
Protection rating is determined by taking into account the effects of both permeation and degradation in an attempt to provide users with an overall protection guideline when using our glove products against specific chemicals.
Used for high chemical exposure or chemical immersion, limited to BTT based on a working day.
Used for repeated chemical contact, limited to total chemical exposure i.e. : accumulative BTT based on a working day.
Splash protection only, on chemical exposure the gloves should be discarded and new gloves worn as soon as possible.
Not recommended, these gloves are deemed unsuitable for work with this chemical.
NT : Not tested
NA : Not applicable because not fully tested (only degradation OR permeation results)
The chemical test data and overall chemical protection rating should not be used as the absolute basis for glove selection. Actual in-use conditions may vary glove performance from the controlled conditions of laboratory tests. Factors other than chemical contact time, such as concentration and temperature, glove thickness and glove reuse, may also affect performance. Other glove requirements, such as length, dexterity, cut, abrasion, puncture and snag resistance, or glove grip also need to be considered in making your final selection.