StanSolv AF-18

Light weight for standard chemical protection

  • Excellent dexterity, due to the suppleness of the glove
  • Flock lining offers added comfort and absorbs perspiration during extended wear
  • Unique Z-pattern grip provides an excellent grip, even on hard-to-grasp materials.

Specific features

Two Tone wear indicator

Applications

  • Automotive/mechanical industry
    • Assembly of small oily parts
    • Assembly of small, oil and grease free parts
  • Chemical industry
    • Common handling Tasks
    • Handling and transporting chemicals (solvents)

Product details

  • Cat. 3
  • Mechanical hazards EN 388
    4101
  • Specific Chemical Protection EN 374
    JKL
  • Micro-organisms EN 374
Material Nitrile
Colour Green
Interior Finish Flocked
Exterior Finish Embossed texture
Length (inches) 13"
Thickness (inches) .018 (18 mil)
Size 6 7 8 9 10 11
Packaging 12 pairs/bag
72 pairs/carton

Operating instructions

Instructions for use

  • It is recommended to check that the gloves are suitable for the intended use, because the conditions of use at workplace may differ from the "CE"-type tests.
  • Persons sensitized to dithiocarbamates and thiazoles should not use these gloves.
  • Put the gloves on dry, clean hands.
  • Do not use the gloves in contact with a chemical for a duration in excess of the measured breakthrough time. Refer to the website www.mapa-pro.com or contact the Technical Customer Service - MAPA PROFESSIONNEL (stc.mapaspontex@mapaspontex.fr) in order to know this breakthrough time. Use 2 pairs alternatively when in long duration contact with a solvent.
  • Turn the cuff end down in order to prevent a hazardous chemical from dripping onto the arm.
  • Inspect the gloves for cracks or snags before reusing them.

Storage conditions

Store the gloves in their original packaging protected from light, humidity and heat.

Laundering conditions

Before taking off the gloves, clean them as appropriate :

  • in use with paints, pigments and inks : wipe with a clean cloth dampened with a suitable solvent, and rub over with a dry cloth
  • in use with a solvent (alcohols, diluents, etc.) : rub over with a dry cloth
  • in use with acids or alkalies : thoroughly rinse the gloves in use with under running water, and rub over with a dry cloth

Caution : improper use of the gloves or submitting them to any cleaning or laundering process which is not specifically recommended can alter their performance levels.

Drying conditions

Ensure the inside of the gloves is dry before putting them on again.

Legislation

This product is not classified as hazardous according to the directive 1999/45/EC of the European Parliament and of the Council.

This product does not contain any substances of very high concern according to the regulation n° 1907/2006 of the European Parliament and of the Council (REACH).

Documentation

Choose the type of documents you want
Send or download the documentation

You can either send the documentation to an e-mail address, or download it.

An email containing the selected documentation will be sent

If your selection includes more than one document, a ZIP archive containing the documentation will be created.

Chemical chart

Chemical Product CAS # BTT
(minutes)
Permeation
level
Standard Degradation
level
Rating
1,1,1-Trichloroethane 99% 71-55-6 91 3 ASTM F739 1
-
1,1,2,2-Tetrachloroethane 98% 79-34-5 44 2 ASTM F739 1
-
1,2 - dichloroethane 99% 107-06-2 7 0 ASTM F739 1
-
1,3 - Dichlorobenzene 98% 541-73-1 37 2 ASTM F739 1
-
1,3 Ethoxy propionate (Ethyl 3-ethoxypropionate) 99% 763-69-9 123 4 ASTM F739 3
++
2-(2-Butoxyethoxy) ethanol 99% 112-34-5 NT NT 4
NA
2-Butoxyethanol (Butyl Cellusolve) 99% 111-76-2 474 5 ASTM F739 4
++
2-Ethoxyethyl acetate (Cellosolve Acetate) 99% 111-15-9 104 3 ASTM F739 2
+
2-Propanol (Isopropanol) 99% 67-63-0 480 6 ASTM F739 4
++
2-Pyrrolidine 99% 123-75-1 NT NT 1
NA
2,2,2-Trifluoroethanol 99% 75-89-8 14 1 ASTM F739 1
-
Acetic acid 99% 64-19-7 93 3 ASTM F739 NT
NA
Ammonium hydroxide solution 29% 1336-21-6 374 5 ASTM F739 4
++
Aniline 99% 62-53-3 88 3 ASTM F739 1
-
Benzene 99% 71-43-2 18 1 ASTM F739 1
-
Butyl Acetate 99% 123-86-4 41 2 ASTM F739 2
=
Carbon Tetrachloride 99% 56-23-5 352 5 ASTM F739 NT
NA
Cyclohexane 99% 110-82-7 480 6 ASTM F739 4
++
Cyclopentanone 99% 120-92-3 NT NT 1
NA
Diethylamine 98% 109-89-7 34 2 ASTM F739 3
+
Dimethylsulfoxide 99% 67-68-5 127 4 ASTM F739 2
+
Ethanol 95% 64-17-5 467 5 ASTM F739 4
++
Ether (Diethyl Ether) 99% 60-29-7 58 2 ASTM F739 4
+
Isobutyl alcohol 99% 78-83-1 NT NT 4
NA
Kerosene mixture 8008-20-6 480 6 ASTM F739 4
++
Methanol 85% 67-56-1 NT NT 4
NA
Methanol 99% 67-56-1 63 3 ASTM F739 4
++
Methylisobutylketone 99% 108-10-1 41 2 ASTM F739 1
-
n-Heptane 99% 142-82-5 480 6 ASTM F739 4
++
n-hexane 95% 110-54-3 480 6 ASTM F739 4
++
N-methyl-2-Pyrrolidone 99% 872-50-4 27 1 ASTM F739 1
-
N-N dimethyl acetamide 99% 127-19-5 25 1 ASTM F739 1
-
Naphtha mixture 8030-30-6 480 6 ASTM F739 4
++
Naphtha VM&P mixture 8032-32-4 NT NT 4
NA
Nitric acid 50% 7697-37-2 185 4 ASTM F739 3
++
Nitric acid 70% 7697-37-2 39 2 ASTM F739 1
-
Petroleum Distillates Hydrotreated Light mixture 64742-47-8 480 6 ASTM F739 4
++
Phenol 85% 108-95-2 223 4 ASTM F739 2
+
Phosphoric acid 75% 7664-38-2 480 6 ASTM F739 4
++
Phosphoric acid 85% 7664-38-2 480 6 ASTM F739 4
++
Potassium Hydroxide 50% 1310-58-3 480 6 ASTM F739 4
++
Sodium hydroxide 20% 1310-73-2 480 6 ASTM F739 4
++
Sodium hydroxide 40% 1310-73-2 480 6 ASTM F739 4
++
Sodium hydroxide 50% 1310-73-2 480 6 ASTM F739 4
++
Styrene 99% 100-42-5 14 1 EN 374-3:2003 NT
NA
Sulfuric acid 10% 7664-93-9 480 6 ASTM F739 4
++
Sulfuric acid 40% 7664-93-9 480 6 ASTM F739 4
++
Sulfuric acid 50% 7664-93-9 480 6 ASTM F739 4
++
t-Butyl Methyl Ether 98% 1634-04-4 374 5 ASTM F739 4
++
Tetrachloroethylene (Perchloroethylene) 99% 127-18-4 196 4 ASTM F739 3
++
Toluene 99% 108-88-3 21 1 ASTM F739 1
-
Unleaded gasoline mixture 8006-61-9 480 6 ASTM F739 4
++
Xylene 99% 1330-20-7 55 2 ASTM F739 2
=

*not normalized result

Overall Chemical Protection Rating

Protection rating is determined by taking into account the effects of both permeation and degradation in an attempt to provide users with an overall protection guideline when using our glove products against specific chemicals.

Used for high chemical exposure or chemical immersion, limited to BTT based on a working day.

Used for repeated chemical contact, limited to total chemical exposure i.e. : accumulative BTT based on a working day.

Splash protection only, on chemical exposure the gloves should be discarded and new gloves worn as soon as possible.

Not recommended, these gloves are deemed unsuitable for work with this chemical.

NT : Not tested

NA : Not applicable because not fully tested (only degradation OR permeation results)

The chemical test data and overall chemical protection rating should not be used as the absolute basis for glove selection. Actual in-use conditions may vary glove performance from the controlled conditions of laboratory tests. Factors other than chemical contact time, such as concentration and temperature, glove thickness and glove reuse, may also affect performance. Other glove requirements, such as length, dexterity, cut, abrasion, puncture and snag resistance, or glove grip also need to be considered in making your final selection.